Welcome to Shanghai HI RUN system control Co., Ltd!

Contact us Collection site Online Message

National Service Hotline 021-63526338
  • Home
  • About Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/about/ —— About Us {/dede:channel}
  • Product Center
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Product Center/ —— Product Center {/dede:channel}
  • News Information
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/News Information/ —— News Information {/dede:channel}
  • Engineering Case
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Engineering Case/ —— Engineering Case {/dede:channel}
  • Sales Outlets
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Sales Outlets/ —— Sales Outlets {/dede:channel}
  • Download
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /Download/ —— Download {/dede:channel}
  • Contact Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Contact Us/ —— Contact Us {/dede:channel}
  • Online Message

Hot keyword search:

EN 50264 Medium Wall Power & C Location:Home> > English > Product Center > Rolling Stock Cables > EN 50264 Medium Wall Power & C >

FIREROL FRL-MW-1SU-PH15/30, FRL-MW-3SU-PH15/30

Article source:http://www.trcables.com/   author:上海嗨润   Release time:2018-01-30 11:02   Browse times:second

EN 50264 Medium Wall Power & Control Cable

FIREROL FRL-MW-1SU-PH15/30, FRL-MW-3SU-PH15/30
0.6/1 or 1.8/3 kV - single core

EN 50264 FRL-MW-1SU-PH15/30, FRL-MW-3SU-PH15/30

Application

-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.

-Used in control,l auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5

Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 106 to EI 109)

Electrical & Mechanical Properties

Nominal Voltage 0.6/1 kV or 1.8/3 kV
Maximum Conductor Temperature +90 deg (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
  4 x Overall Diameter (D>12mm)

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali
EN 50305 Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Low Toxicity
NFF 16101; NFF 63808; BS6853 Smoke index
EN50200: 2000 Resistance to fire of unprotected small cable for use in emergency circuits 4 classifications are defined: PH 15,30,60, or 90mins;
IEC60331-21 The circuit integrity test under fire of cables rated 0.6/1.0kV and below

FRL-MW-1SU-PH15/30 0.6/1 kV

Nominal
Cross-Sectional
Area

 

Conductor
Diameter
(a)

 

 Min. Mean
Thickness
of Insulation

 

Overall Diameter

 

Weight

  Conductor Resistance  

Insulation Resistance

 
Min.   Max.   20°C   20°C   90°C  
mm2   mm   mm   mm   mm   kg/km   Ω/km   MΩ x km   MΩ x km  
1.0   1.25   0.6   2.6   3.1   15   20   11.4   0.114  
1.5   1.5   0.7   3.0   3.6   24   13.7   11.0   0.110  
2.5   1.95   0.7   3.4   4.1   36   8.21   9.1   0.091  
4   2.5   0.7   4.0   4.7   54   5.09   7.5   0.075  
6   3.0   0.7   4.4   5.3   76   3.39   6.5   0.065  
10   3.9   0.7   5.3   6.2   121   1.95   5.2   0.052  
16   5.0   0.7   6.3   7.5   184   1.24   4.2   0.042  
25   6.4   0.9   8.0   9.4   289   0.795   4.1   0.041  
35   7.7   0.9   9.2   10.9   395   0.565   3.5   0.035  
50   9.2   1.0   10.8   12.7   563   0.393   3.3   0.033  
70   11.0   1.1   12.7   14.9   796   0.277   3.0   0.030  
95   12.5   1.1   14.1   16.6   1032   0.210   2.7   0.027  
120   14.2   1.2   15.9   18.7   1318   0.164   2.7   0.027  
150   15.8   1.4   17.8   20.9   1650   0.132   2.7   0.027  
185   17.5   1.6   19.8   23.2   2018   0.108   2.6   0.026  
240   20.1   1.7   22.4   26.3   2649   0.0817   2.6   0.026  
300   22.5   1.8   24.8   29.1   3291   0.0654   2.4   0.024  
400   25.8   2.0   28.3   33.2   3850   0.0495   2.4   0.024  

FRL-MW-3SU-PH15/30 1.8/3 kV

Nominal
Cross-Sectional
Area

 

Conductor
Diameter
(a)

 

 Min. Mean
Thickness
of Insulation

 

Overall Diameter

 

Weight

  Conductor Resistance  

Insulation Resistance

 
Min.   Max.   20°C   20°C   90°C  
mm2   mm   mm   mm   mm   kg/km   Ω/km   MΩ x km   MΩ x km  
1.5   1.5   2.0   5.5   6.5   56   13.7   21.0   0.210  
2.5   1.95   2.0   5.9   7.0   71   8.21   18.0   0.180  
4   2.5   2.0   6.4   7.6   90   5.09   15.5   0.155  
6   3.0   2.0   69   8.1   114   3.39   13.7   0.137  
10   3.9   2.0   7.7   9.1   165   1.95   11.5   0.115  
16   5.0   2.0   8.8   10.3   235   1.24   9.5   0.095  
25   6.4   2.0   10.1   11.9   320   0.795   7.9   0.079  
35   7.7   2.0   11.3   13.3   440   0.565   6.8   0.068  
50   9.2   2.0   12.7   14.9   610   0.393   5.9   0.059  
70   11.0   2.0   14.4   16.9   850   0.277   5.0   0.050  
95   12.5   2.2   16.2   19.0   1110   0.210   4.5   0.045  
120   14.2   2.2   17.8   20.9   1400   0.164   4.0   0.040  
150   15.8   2.2   19.3   22.6   1710   0.132   3.7   0.037  
185   17.5   2.4   21.1   24.7   2110   0.108   3.4   0.034  
240   20.1   2.4   23.9   27.8   2750   0.0817   3.0   0.030  
300   22.5   2.4   25.8   30.4   3300   0.0654   2.7   0.027  
400   25.8   2.6   29.4   34.5   3900   0.0495   2.4   0.024  

(a)= For information,indicative only